Worcester Bosch · E9 224
E9 224 on a Worcester Bosch boiler
Your Worcester Bosch has stopped and the display says E9 224. This page explains the code, the checks you can safely make and when you need us.
- Gas Safe registered engineers
- Fixed quote before work
- Flats, houses and lettings
Quick help
Boiler showing a fault code? Write it down before you reset it, then call:
Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed
What the boiler is telling you
With E9 224, the flue thermostat or the high-limit thermostat has operated. It shows your boiler got hotter than it should, so it shut down. Try the simple checks below first; if the code returns, call an engineer.
Codes can differ between models, so check the fault table in your manual too. In converted flats with a rear lightwell, condensate pipes often run down a cold outside wall, so freezing-related lockouts happen here more than you might expect in central London.
What usually causes it
Possible causes include:
- Low pressure or air in the system
- Sludge or scale in the heat exchanger
- A flue or sensor fault
- Poor circulation from a sticking pump
Before you call: safe checks
1. Look at the pressure dial
With the heating off and your boiler cool, read the pressure dial on the front of your boiler. Most boilers want roughly 1 to 1.5 bar when cold, though the manual for your boiler is the final word. If it reads below 1 bar, you can normally refill it yourself using the filling loop, a short braided hose or a built-in key under your boiler. Open the valves slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If you find yourself topping up every week, water is escaping somewhere and that's a job for an engineer.
2. Let trapped air out of the radiators
Trapped air upsets circulation and can make your boiler overheat. With everything cold, open the bleed screw on each radiator until a drop of water shows. Afterwards, check the pressure again, because bleeding lets water out.
3. Try a single reset
Use the reset button on the front panel: Worcester Bosch asks you to hold it for about five seconds. Give it a few minutes to run through its start-up. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.
Anything behind the casing, and any gas or flue work, must be left to a Registered Gas Safe engineer. Smell gas? Get outside and call 0800 111 999.
When to stop and call us
If E9 224 returns, leave your boiler off: an engineer needs to find out why it's overheating.
Need a hand in Kensington? Call 020 3507 1068 or send us the details and we'll call you back. We're open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Codes that are often confused with this one
- Overheat / safety thermostat: Baxi E110
- Circulation fault: Baxi E125
- Pump or water shortage fault: Vaillant F.75
- All Worcester Bosch codes
- Boiler breakdown help in Kensington
Questions
Can I reset E9 224?
Once, after checking the pressure. If it returns, don't keep resetting: an engineer needs to find out why your boiler is overheating.