EA 227 on a Worcester Bosch boiler

Your Worcester Bosch has stopped and the display says EA 227. Below: the meaning, the likely causes and the point at which to stop and call.

  • Gas Safe registered engineers
  • Fixed quote before work
  • Flats, houses and lettings

Quick help

Boiler showing a fault code? Write it down before you reset it, then call:

020 3507 1068

Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

What the boiler is telling you

On a Worcester Bosch Greenstar, EA with cause code 227 is an ignition lockout: no flame was detected. Worcester's literature points owners to three checks: gas, condensate and flue. Some causes are simple to rule out, others need a Registered Gas Safe engineer.

Meanings vary a little between models; your manual has the definitive list. Most of our calls in Queen's Gate and Gloucester Road are from flats, where a leak or lockout can affect the neighbours as well.

What usually causes it

The manufacturer's fault table and day-to-day experience point to:

  • A blocked flue outlet
  • Gas off or a prepayment meter with no credit
  • A worn ignition or flame-sensing electrode
  • A frozen or blocked condensate pipe
  • A gas valve or PCB fault

Before you call: safe checks

1. Make sure gas is reaching the house

See whether another gas appliance, such as the hob, lights. On a prepayment meter, check the credit and any emergency credit, as running out is a common cause of ignition lockouts. Nothing on the gas side of your boiler is a DIY job. If you smell gas, ring 0800 111 999 from outside the property.

2. Check for a frozen condensate pipe

The condensate pipe is the plastic pipe that carries water from your boiler to a drain, often outside. If it's frozen, your boiler may gurgle and then lock out. Provided you can reach the pipe safely from the ground, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset your boiler. Leave pipes at height to an engineer.

3. Check nothing is blocking the flue

From outside, check that nothing obvious is blocking the flue terminal, such as plants, a cover or a nest. Don't touch, remove or alter any part of the flue: any damage or blockage is a job for a Registered Gas Safe engineer.

4. Use the reset button, once

Use the reset button on the front panel: on a Greenstar, hold it for around five seconds. Allow a little time for your boiler to try again. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.

Never remove your boiler casing or touch the gas valve, gas pipes or flue. Smell gas? Get outside and call 0800 111 999.

When to stop and call us

Once you've done the outside checks, any repeat EA 227 is for an engineer: which only a Registered Gas Safe engineer should do.

Ring 020 3507 1068 with the code and your boiler's model, or use our enquiry form. We're open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Codes that are often confused with this one

Questions

What does EA 227 mean on a Worcester Bosch?

No flame was detected when your boiler tried to light. Check the gas supply, the condensate pipe and the flue outlet, then reset.

Can you fix a Worcester Bosch boiler in Kensington?

We do. Our Registered Gas Safe engineers repair Worcester Bosch boilers across W8, W14, SW5 and SW7, including Gloucester Road and Olympia. Call 020 3507 1068 with the code.

Need a heating engineer in Kensington?

Speak to us on 020 3507 1068, email [email protected] or book online.

Opening hours: Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

Call 020 3507 1068Book